کنترل فاز دیجیتال شیوا امواج مدل DMB-600S
تومان440.000

کنتاکت کمکی 1 باز 1 بسته برند JBH
تومان135.000 تومان131.000
کنتاکتور 32آمپری LC1D32E7 اشنایدر الکتریک
کنتاکتور 32آمپری اشنایدر الکتریک 3پل 3باز با بوبین 48ولت متناوب
TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 32 A – 48 V AC coil Main range TeSys product name TeSys D product or component type Contactor device short name LC1D contactor application Motor control Resistive load utilisation category AC-1 AC-3 AC-4 poles description 3P pole contact composition 3 NO System Voltage < = 300 V DC power circuit< = 690 V AC 25…400 Hz power circuit [Ie] rated operational current 32 A (<= 140 °F (60 °C)) at <= 440 V AC AC-3 power circuit 50 A (<= 140 °F (60 °C)) at <= 440 V AC AC-1 power circuit motor power kW 15 kW at 380…400 V AC 50/60 Hz AC-3 7.5 kW at 220…230 V AC 50/60 Hz AC-3 18.5 kW at 500 V AC 50/60 Hz AC-3 18.5 kW at 660…690 V AC 50/60 Hz AC-3 15 kW at 415…440 V AC 50/60 Hz AC-3 7.5 kW at 400 V AC 50/60 Hz AC-4 motor power hp 2 hp at 115 V AC 50/60 Hz 1 phase motors 5 hp at 230/240 V AC 50/60 Hz 1 phase motors 7.5 hp at 200/208 V AC 50/60 Hz 3 phases motors 10 hp at 230/240 V AC 50/60 Hz 3 phases motors 20 hp at 460/480 V AC 50/60 Hz 3 phases motors 30 hp at 575/600 V AC 50/60 Hz 3 phases motors control circuit type AC 50/60 Hz [Uc] control circuit voltage 48 V AC 50/60 Hz auxiliary contact composition 1 NO + 1 NC [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947 overvoltage category III [Ith] conventional free air thermal current 50 A at <= 140 °F (60 °C) power circuit 10 A at <= 140 °F (60 °C) signalling circuit Irms rated making capacity 550 A at 440 V power circuit conforming to IEC 60947 140 A AC signalling circuit conforming to IEC 60947-5-1 250 A DC signalling circuit conforming to IEC 60947-5-1 rated breaking capacity 550 A at 440 V power circuit conforming to IEC 60947 [Icw] rated short-time withstand current 138 A <= 104 °F (40 °C) 1 min power circuit 260 A <= 104 °F (40 °C) 10 s power circuit 430 A <= 104 °F (40 °C) 1 s power circuit 60 A <= 104 °F (40 °C) 10 min power circuit 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit associated fuse rating 63 A gG at <= 690 V coordination type 1 power circuit 63 A gG at <= 690 V coordination type 2 power circuit 10 A gG signalling circuit conforming to IEC 60947-5-1 average impedance 2 mOhm at 50 Hz – Ith 50 A power circuit [Ui] rated insulation voltage 600 V power circuit certifications CSA 600 V power circuit certifications UL 690 V power circuit conforming to IEC 60947-4-1 690 V signalling circuit conforming to IEC 60947-1 600 V signalling circuit certifications CSA 600 V signalling circuit certifications UL electrical durability 1.65 Mcycles 32 A AC-3 at Ue <= 440 V 1.4 Mcycles 50 A AC-1 at Ue <= 440 V power dissipation per pole 2 W AC-3 5 W AC-1 protective cover With mounting support Plate Rail standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 product certifications BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL connections – terminals Control circuit: screw clamp terminals 2 cable(s) 0…0 in² (1…2.5 mm²) – cable stiffness: flexible – with cable end Power circuit: screw clamp terminals 1 cable(s) 0…0.02 in² (1.5…10 mm²) – cable stiffness: solid – without cable end Control circuit: screw clamp terminals 1 cable(s) 0…0.01 in² (1…4 mm²) – cable stiffness: flexible – without cable end Control circuit: screw clamp terminals 2 cable(s) 0…0.01 in² (1…4 mm²) – cable stiffness: flexible – without cable end Control circuit: screw clamp terminals 1 cable(s) 0…0.01 in² (1…4 mm²) – cable stiffness: flexible – with cable end Control circuit: screw clamp terminals 1 cable(s) 0…0.01 in² (1…4 mm²) – cable stiffness: solid – without cable end Control circuit: screw clamp terminals 2 cable(s) 0…0.01 in² (1…4 mm²) – cable stiffness: solid – without cable end Power circuit: screw clamp terminals 1 cable(s) 0…0.02 in² (2.5…10 mm²) – cable stiffness: flexible – without cable end Power circuit: screw clamp terminals 2 cable(s) 0…0.02 in² (2.5…10 mm²) – cable stiffness: flexible – without cable end Power circuit: screw clamp terminals 1 cable(s) 0…0.02 in² (1…10 mm²) – cable stiffness: flexible – with cable end Power circuit: screw clamp terminals 2 cable(s) 0…0.01 in² (1.5…6 mm²) – cable stiffness: flexible – with cable end Power circuit: screw clamp terminals 2 cable(s) 0…0.02 in² (2.5…10 mm²) – cable stiffness: solid – without cable end tightening torque Control circuit: 15.04 lbf.in (1.7 N.m) – on screw clamp terminals – with screwdriver flat Ø 6 mm Control circuit: 15.04 lbf.in (1.7 N.m) – on screw clamp terminals – with screwdriver Philips No 2 Power circuit: 22.12 lbf.in (2.5 N.m) – on screw clamp terminals – with screwdriver flat Ø 6 mm Power circuit: 22.12 lbf.in (2.5 N.m) – on screw clamp terminals – with screwdriver Philips No 2 operating time 4…19 ms opening 12…22 ms closing safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 mechanical durability 15 Mcycles operating rate 3600 cyc/h at <= 140 °F (60 °C) Complementary coil technology Without built-in suppressor module control circuit voltage limits 0.3…0.6 Uc drop-out at 140 °F (60 °C), AC 50/60 Hz 0.8…1.1 Uc operational at 140 °F (60 °C), AC 50 Hz 0.85…1.1 Uc operational at 140 °F (60 °C), AC 60 Hz inrush power in VA 70 VA at 68 °F (20 °C) (cos ϕ 0.75) 60 Hz 70 VA at 68 °F (20 °C) (cos ϕ 0.75) 50 Hz hold-in power consumption in VA 7.5 VA at 68 °F (20 °C) (cos ϕ 0.3) 60 Hz 7 VA at 68 °F (20 °C) (cos ϕ 0.3) 50 Hz heat dissipation 2…3 W at 50/60 Hz auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1 Type mirror contact (1 NC) conforming to IEC 60947-4-1 signalling circuit frequency 25…400 Hz minimum switching current 5 mA signalling circuit minimum switching voltage 17 V signalling circuit non-overlap time 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact insulation resistance > 10 MOhm signalling circuit
Environment IP degree of protection
IP20 front face conforming to IEC 60529
protective treatment
TH conforming to IEC 60068-2-30
pollution degree
3
ambient air temperature for operation
23…140 °F (-5…60 °C)
ambient air temperature for storage
-76…176 °F (-60…80 °C)
permissible ambient air temperature around the device
-40…158 °F (-40…70 °C) at Uc
operating altitude
9842.52 ft (3000 m) without derating in temperature
fire resistance
1562 °F (850 °C) conforming to IEC 60695-2-1
flame retardance
V1 conforming to UL 94
mechanical robustness
Vibrations contactor open 2 Gn, 5…300 Hz
Vibrations contactor closed 4 Gn, 5…300 Hz
Shocks contactor closed 15 Gn for 11 ms
Shocks contactor open 8 Gn for 11 ms
height
3.35 in (85 mm)
width
1.77 in (45 mm)
depth
3.62 in (92 mm)
product weight
0.83 lb(US) (0.375 kg)